📞 +966 54 126 7359
📞 +91 9526151069
✉ info@west-velocity.com
Motor Protection Circuit Breakers (MPCB) BCH MS32-32 Motor Protection …

BCH MS32-32 Motor Protection Switch MPCB (25-32 A)

Brand: BCH
SKU: MS32-32
MPN: MS32-32
Made in India
Contact for pricing
Available in Saudi Arabia

BCH MS32-32 motor protection switch with thermal and magnetic releases, setting range 25-32 A. Manual START / STOP push-buttons with trip indication, automatic switch-off at over-current, sensitivity to phase failure and trip class 10. Mounts on a 35 mm rail (EN 60715) in vertical or horizontal position and can be controlled with an under-voltage or shunt release.

Specifications

Cat CodeMS32-32
Setting Range (A)25-32
Operating Current of Short-Circuit Release (A)400
Icu / Ics at 230 V (kA)25 / 12.5
Icu / Ics at 400 V (kA)25 / 12.5
Icu / Ics at 500 V (kA)4 / 3
Icu / Ics at 690 V (kA)3 / 2
Max. Back-up Fuse (gL) if Icp > Icu230 V: 80 A; 400 V: 80 A; 500 V: 50 A; 690 V: 50 A
Standard Motor Power 3-Phase 220-240V (kW)7.5
Standard Motor Power 3-Phase 380-415V (kW)15
Standard Motor Power 3-Phase 440V (kW)15
Standard Motor Power 3-Phase 500V (kW)18.5
Standard Motor Power 3-Phase 660-690V (kW)22
StandardsIEC/EN 60947-2, IEC/EN 60947-4-1, IEC/EN 60947-5-1, IEC/EN 60204, UL 508, CSA 22.2 No.14
ApprovalsUL
Max. Operational Voltage Ue690 V
No. of Poles3
Operating Current of Thermal Overload Release1.05 Ir < I ≤ 1.20 Ir (Ir = current setting value)
Sensitivity to Phase Failureyes
Power Dissipation per Pole at Upper Setting Limit2 - 2.5 W
Utilization CategoryAC-3 (IEC/EN 60947-4-1); A (IEC/EN 60947-2)
Trip Class (IEC/EN 60947-4-1)10
Degree of ProtectionIP20, after terminals covering IP40
Ambient Temperature-25 ... +60 °C
Storage Temperature-25 ... +70 °C
Thermal Compensation Range-5 ... +40 °C
Mechanical and Electrical Endurance100,000 op.
Max. Operating Cycles25 op./h
Shock Resistance (IEC 68-2-27)20 g
Vibration Resistance (IEC 68-2-6)5 g at f = 5 ... 150 Hz
Overvoltage Category / Pollution DegreeIII / 3
Rated Insulation Voltage Ui690 V
Rated Impulse Withstand Voltage Uimp6 kV
Weight0.279 kg
Terminal Capacityrigid 0.75 ... 10 mm²; flexible 0.75 ... 6 mm²
Screw Head / Tightening TorquePZ2 / 2.0 Nm
Isolating Distance between Contacts4.5 mm per contact place
Mounting35 mm wide rail (EN 60715), vertical or horizontal position

Ordering / Variants

Thermal-release-only version MSB32-32 (max. 400 V; max. back-up fuse 50 A gL at Ue < 400 V); accessories: HS side auxiliary switch, HSV / HRS contact blocks, UR under-voltage / AR shunt release, HO-41/55 enclosure, FP-41/55 frame, P-41/55 front plate, MSK07 / MSKNL9 / MSKNL22 contactor adapters.

Datasheet, certificates and quotation on request - info@west-velocity.com.

Login to Buy WhatsApp